]> git.saurik.com Git - wxWidgets.git/blob - docs/latex/wx/recrdset.tex
?lk
[wxWidgets.git] / docs / latex / wx / recrdset.tex
1 \section{\class{wxRecordSet}}\label{wxrecordset}
2
3 Each wxRecordSet represents an ODBC database query. You can make multiple queries
4 at a time by using multiple wxRecordSets with a wxDatabase or you can make
5 your queries in sequential order using the same wxRecordSet.
6
7 \wxheading{Derived from}
8
9 \helpref{wxObject}{wxobject}
10
11 \wxheading{Include files}
12
13 <wx/odbc.h>
14
15 \wxheading{See also}
16
17 \helpref{wxRecordSet overview}{wxrecordsetoverview}, \helpref{wxDatabase overview}{wxdatabaseoverview}
18
19 \latexignore{\rtfignore{\wxheading{Members}}}
20
21 \membersection{wxRecordSet::wxRecordSet}
22
23 \func{}{wxRecordSet}{\param{wxDatabase *}{db}, \param{int}{ type = wxOPEN\_TYPE\_DYNASET},
24 \param{int}{ opt = wxOPTION\_DEFAULT}}
25
26 Constructor. {\it db} is a pointer to the wxDatabase instance you wish to use the
27 wxRecordSet with. Currently there are two possible values of {\it type}:
28
29 \begin{itemize}\itemsep=0pt
30 \item wxOPEN\_TYPE\_DYNASET: Loads only one record at a time into memory. The other
31 data of the result set will be loaded dynamically when
32 moving the cursor. This is the default type.
33 \item wxOPEN\_TYPE\_SNAPSHOT: Loads all records of a result set at once. This will
34 need much more memory, but will result in
35 faster access to the ODBC data.
36 \end{itemize}
37
38 The {\it option} parameter is not used yet.
39
40 The constructor appends the wxRecordSet object to the parent database's list of
41 wxRecordSet objects, for later destruction when the wxDatabase is destroyed.
42
43 \membersection{wxRecordSet::\destruct{wxRecordSet}}
44
45 \func{}{\destruct{wxRecordSet}}{\void}
46
47 Destructor. All data except that stored in user-defined variables will be lost.
48 It also unlinks the wxRecordSet object from the parent database's list of
49 wxRecordSet objects.
50
51 \membersection{wxRecordSet::AddNew}
52
53 \func{void}{AddNew}{\void}
54
55 Not implemented.
56
57 \membersection{wxRecordSet::BeginQuery}
58
59 \func{bool}{BeginQuery}{\param{int}{ openType}, \param{const wxString\& }{sql = NULL}, \param{int}{ options = wxOPTION\_DEFAULT}}
60
61 Not implemented.
62
63 \membersection{wxRecordSet::BindVar}
64
65 \func{void *}{BindVar}{\param{int}{ col}, \param{void *}{buf}, \param{long}{ size}}
66
67 Binds a user-defined variable to the column col. Whenever the current field's
68 data changes, it will be copied into buf (maximum {\it size} bytes).
69
70 \func{void *}{BindVar}{\param{const wxString\& }{col}, \param{void *}{buf}, \param{long}{ size}}
71
72 The same as above, but uses the column name as the identifier.
73
74 \membersection{wxRecordSet::CanAppend}
75
76 \func{bool}{CanAppend}{\void}
77
78 Not implemented.
79
80 \membersection{wxRecordSet::Cancel}
81
82 \func{void}{Cancel}{\void}
83
84 Not implemented.
85
86 \membersection{wxRecordSet::CanRestart}
87
88 \func{bool}{CanRestart}{\void}
89
90 Not implemented.
91
92 \membersection{wxRecordSet::CanScroll}
93
94 \func{bool}{CanScroll}{\void}
95
96 Not implemented.
97
98 \membersection{wxRecordSet::CanTransact}
99
100 \func{bool}{CanTransact}{\void}
101
102 Not implemented.
103
104 \membersection{wxRecordSet::CanUpdate}
105
106 \func{bool}{CanUpdate}{\void}
107
108 Not implemented.
109
110 \membersection{wxRecordSet::ConstructDefaultSQL}
111
112 \func{bool}{ConstructDefaultSQL}{\void}
113
114 Not implemented.
115
116 \membersection{wxRecordSet::Delete}
117
118 \func{bool}{Delete}{\void}
119
120 Deletes the current record. Not implemented.
121
122 \membersection{wxRecordSet::Edit}
123
124 \func{void}{Edit}{\void}
125
126 Not implemented.
127
128 \membersection{wxRecordSet::EndQuery}
129
130 \func{bool}{EndQuery}{\void}
131
132 Not implemented.
133
134 \membersection{wxRecordSet::ExecuteSQL}\label{wxrecordsetexecutesql}
135
136 \func{bool}{ExecuteSQL}{\param{const wxString\& }{sql}}
137
138 Directly executes a SQL statement. The data will be presented as a normal
139 result set. Note that the recordset must have been created as a snapshot, not
140 dynaset. Dynasets will be implemented in the near future.
141
142 Examples of common SQL statements are given in \helpref{A selection of SQL commands}{sqlcommands}.
143
144 \membersection{wxRecordSet::FillVars}
145
146 \func{void}{FillVars}{\param{int}{ recnum}}
147
148 Fills in the user-defined variables of the columns. You can set these
149 variables with wxQueryCol::BindVar. This function will be automatically
150 called after every successful database operation.
151
152 \membersection{wxRecordSet::GetColName}
153
154 \func{wxString}{GetColName}{\param{int}{ col}}
155
156 Returns the name of the column at position {\it col}. Returns NULL if {\it col} does not
157 exist.
158
159 \membersection{wxRecordSet::GetColType}
160
161 \func{short}{GetColType}{\param{int}{ col}}
162
163 Returns the data type of the column at position {\it col}. Returns SQL\_TYPE\_NULL
164 if {\it col} does not exist.
165
166 \func{short}{GetColType}{\param{const wxString\& }{ name}}
167
168 The same as above, but uses the column name as the identifier.
169
170 See \helpref{ODBC SQL data types}{sqltypes} for a list
171 of possible data types.
172
173 \membersection{wxRecordSet::GetColumns}
174
175 \func{bool}{GetColumns}{\param{const wxString\& }{table = NULL}}
176
177 Returns the columns of the table with the specified name. If no name is
178 given the class member {\it tablename} will be used. If both names are NULL
179 nothing will happen. The data will be presented as a normal result set, organized
180 as follows:
181
182 \begin{twocollist}\itemsep=0pt
183 \twocolitem{0 (VARCHAR)}{TABLE\_QUALIFIER}
184 \twocolitem{1 (VARCHAR)}{TABLE\_OWNER}
185 \twocolitem{2 (VARCHAR)}{TABLE\_NAME}
186 \twocolitem{3 (VARCHAR)}{COLUMN\_NAME}
187 \twocolitem{4 (SMALLINT)}{DATA\_TYPE}
188 \twocolitem{5 (VARCHAR)}{TYPE\_NAME}
189 \twocolitem{6 (INTEGER)}{PRECISION}
190 \twocolitem{7 (INTEGER)}{LENGTH}
191 \twocolitem{8 (SMALLINT)}{SCALE}
192 \twocolitem{9 (SMALLINT)}{RADIX}
193 \twocolitem{10 (SMALLINT)}{NULLABLE}
194 \twocolitem{11 (VARCHAR)}{REMARKS}
195 \end{twocollist}
196
197 \membersection{wxRecordSet::GetCurrentRecord}
198
199 \func{long}{GetCurrentRecord}{\void}
200
201 Not implemented.
202
203 \membersection{wxRecordSet::GetDatabase}
204
205 \func{wxDatabase *}{GetDatabase}{\void}
206
207 Returns the wxDatabase object bound to a wxRecordSet.
208
209 \membersection{wxRecordSet::GetDataSources}\label{wxrecordsetgetdatasources}
210
211 \func{bool}{GetDataSources}{\void}
212
213 Gets the currently-defined data sources via the ODBC manager. The data will be presented
214 as a normal result set. See the documentation for the ODBC function SQLDataSources for how the data
215 is organized.
216
217 Example:
218
219 \begin{verbatim}
220 wxDatabase Database;
221
222 wxRecordSet *Record = new wxRecordSet(&Database);
223
224 if (!Record->GetDataSources()) {
225 char buf[300];
226 sprintf(buf, "%s %s\n", Database.GetErrorClass(), Database.GetErrorMessage());
227 frame->output->SetValue(buf);
228 }
229 else {
230 do {
231 frame->DataSource->Append((char*)Record->GetFieldDataPtr(0, SQL_CHAR));
232 } while (Record->MoveNext());
233 }
234 \end{verbatim}
235
236 \membersection{wxRecordSet::GetDefaultConnect}
237
238 \func{wxString}{GetDefaultConnect}{\void}
239
240 Not implemented.
241
242 \membersection{wxRecordSet::GetDefaultSQL}
243
244 \func{wxString}{GetDefaultSQL}{\void}
245
246 Not implemented.
247
248 \membersection{wxRecordSet::GetErrorCode}
249
250 \func{wxRETCODE}{GetErrorCode}{\void}
251
252 Returns the error code of the last ODBC action. This will be one of:
253
254 \begin{twocollist}\itemsep=0pt
255 \twocolitem{SQL\_ERROR}{General error.}
256 \twocolitem{SQL\_INVALID\_HANDLE}{An invalid handle was passed to an ODBC function.}
257 \twocolitem{SQL\_NEED\_DATA}{ODBC expected some data.}
258 \twocolitem{SQL\_NO\_DATA\_FOUND}{No data was found by this ODBC call.}
259 \twocolitem{SQL\_SUCCESS}{The call was successful.}
260 \twocolitem{SQL\_SUCCESS\_WITH\_INFO}{The call was successful, but further information can be
261 obtained from the ODBC manager.}
262 \end{twocollist}
263
264 \membersection{wxRecordSet::GetFieldData}\label{wxrecordsetgetfielddata}
265
266 \func{bool}{GetFieldData}{\param{int}{ col}, \param{int}{ dataType}, \param{void *}{dataPtr}}
267
268 Copies the current data of the column at position {\it col} into the buffer
269 \rtfsp{\it dataPtr}. To be sure to get the right type of data, the user has to pass the
270 correct data type. The function returns FALSE if {\it col} does not
271 exist or the wrong data type was given.
272
273 \func{bool}{GetFieldData}{\param{const wxString\& }{name}, \param{int}{ dataType}, \param{void *}{dataPtr}}
274
275 The same as above, but uses the column name as the identifier.
276
277 See \helpref{ODBC SQL data types}{sqltypes} for a list
278 of possible data types.
279
280 \membersection{wxRecordSet::GetFieldDataPtr}\label{wxrecordsetgetfielddataptr}
281
282 \func{void *}{GetFieldDataPtr}{\param{int}{ col}, \param{int}{ dataType}}
283
284 Returns the current data pointer of the column at position {\it col}.
285 To be sure to get the right type of data, the user has to pass the
286 data type. Returns NULL if {\it col} does not exist or if {\it dataType} is
287 incorrect.
288
289 \func{void *}{GetFieldDataPtr}{\param{const wxString\& }{name}, \param{int}{ dataType}}
290
291 The same as above, but uses the column name as the identifier.
292
293 See \helpref{ODBC SQL data types}{sqltypes} for a list
294 of possible data types.
295
296 \membersection{wxRecordSet::GetFilter}
297
298 \func{wxString}{GetFilter}{\void}
299
300 Returns the current filter.
301
302 \membersection{wxRecordSet::GetForeignKeys}
303
304 \func{bool}{GetPrimaryKeys}{\param{const wxString\& }{ptable = NULL}, \param{const wxString\& }{ftable
305 = NULL}}
306
307 Returns a list of foreign keys in the specified table (columns in the
308 specified table that refer to primary keys in other tables), or
309 a list of foreign keys in other tables that refer to the primary key in
310 the specified table.
311
312 If {\it ptable} contains a table name, this function returns a result
313 set containing the primary key of the specified table.
314
315 If {\it ftable} contains a table name, this functions returns a result set
316 of containing all of the foreign keys in the specified table and the
317 primary keys (in other tables) to which they refer.
318
319 If both {\it ptable} and {\it ftable} contain table names, this
320 function returns the foreign keys in the table specified in {\it
321 ftable} that refer to the primary key of the table specified in {\it
322 ptable}. This should be one key at most.
323
324 GetForeignKeys returns results as a standard result set. If the foreign
325 keys associated with a primary key are requested, the result set is
326 ordered by FKTABLE\_QUALIFIER, FKTABLE\_OWNER, FKTABLE\_NAME, and KEY\_SEQ.
327 If the primary keys associated with a foreign key are requested, the
328 result set is ordered by PKTABLE\_QUALIFIER, PKTABLE\_OWNER, PKTABLE\_NAME,
329 and KEY\_SEQ. The following table lists the columns in the result set.
330
331 \begin{twocollist}\itemsep=0pt
332 \twocolitem{0 (VARCHAR)}{PKTABLE\_QUALIFIER}
333 \twocolitem{1 (VARCHAR)}{PKTABLE\_OWNER}
334 \twocolitem{2 (VARCHAR)}{PKTABLE\_NAME}
335 \twocolitem{3 (VARCHAR)}{PKCOLUMN\_NAME}
336 \twocolitem{4 (VARCHAR)}{FKTABLE\_QUALIFIER}
337 \twocolitem{5 (VARCHAR)}{FKTABLE\_OWNER}
338 \twocolitem{6 (VARCHAR)}{FKTABLE\_NAME}
339 \twocolitem{7 (VARCHAR)}{FKCOLUMN\_NAME}
340 \twocolitem{8 (SMALLINT)}{KEY\_SEQ}
341 \twocolitem{9 (SMALLINT)}{UPDATE\_RULE}
342 \twocolitem{10 (SMALLINT)}{DELETE\_RULE}
343 \twocolitem{11 (VARCHAR)}{FK\_NAME}
344 \twocolitem{12 (VARCHAR)}{PK\_NAME}
345 \end{twocollist}
346
347 \membersection{wxRecordSet::GetNumberCols}
348
349 \func{long}{GetNumberCols}{\void}
350
351 Returns the number of columns in the result set.
352
353 \membersection{wxRecordSet::GetNumberFields}
354
355 \func{int}{GetNumberFields}{\void}
356
357 Not implemented.
358
359 \membersection{wxRecordSet::GetNumberParams}
360
361 \func{int}{GetNumberParams}{\void}
362
363 Not implemented.
364
365 \membersection{wxRecordSet::GetNumberRecords}
366
367 \func{long}{GetNumberRecords}{\void}
368
369 Returns the number of records in the result set.
370
371 \membersection{wxRecordSet::GetPrimaryKeys}
372
373 \func{bool}{GetPrimaryKeys}{\param{const wxString\& }{table = NULL}}
374
375 Returns the column names that comprise the primary key of the table with the specified name. If no name is
376 given the class member {\it tablename} will be used. If both names are NULL
377 nothing will happen. The data will be presented as a normal result set, organized
378 as follows:
379
380 \begin{twocollist}\itemsep=0pt
381 \twocolitem{0 (VARCHAR)}{TABLE\_QUALIFIER}
382 \twocolitem{1 (VARCHAR)}{TABLE\_OWNER}
383 \twocolitem{2 (VARCHAR)}{TABLE\_NAME}
384 \twocolitem{3 (VARCHAR)}{COLUMN\_NAME}
385 \twocolitem{4 (SMALLINT)}{KEY\_SEQ}
386 \twocolitem{5 (VARCHAR)}{PK\_NAME}
387 \end{twocollist}
388
389 \membersection{wxRecordSet::GetOptions}
390
391 \func{int}{GetOptions}{\void}
392
393 Returns the options of the wxRecordSet. Options are not supported yet.
394
395 \membersection{wxRecordSet::GetResultSet}
396
397 \func{bool}{GetResultSet}{\void}
398
399 Copies the data presented by ODBC into wxRecordSet. Depending on the
400 wxRecordSet type all or only one record(s) will be copied.
401 Usually this function will be called automatically after each successful
402 database operation.
403
404 \membersection{wxRecordSet::GetSortString}
405
406 \func{wxString}{GetSortString}{\void}
407
408 Not implemented.
409
410 \membersection{wxRecordSet::GetSQL}
411
412 \func{wxString}{GetSQL}{\void}
413
414 Not implemented.
415
416 \membersection{wxRecordSet::GetTableName}
417
418 \func{wxString}{GetTableName}{\void}
419
420 Returns the name of the current table.
421
422 \membersection{wxRecordSet::GetTables}
423
424 \func{bool}{GetTables}{\void}
425
426 Gets the tables of a database. The data will be presented as a normal result
427 set, organized as follows:
428
429 \begin{twocollist}\itemsep=0pt
430 \twocolitem{0 (VARCHAR)}{TABLE\_QUALIFIER}
431 \twocolitem{1 (VARCHAR)}{TABLE\_OWNER}
432 \twocolitem{2 (VARCHAR)}{TABLE\_NAME}
433 \twocolitem{3 (VARCHAR)}{TABLE\_TYPE (TABLE, VIEW, SYSTEM TABLE, GLOBAL TEMPORARY, LOCAL TEMPORARY,
434 ALIAS, SYNONYM, or database-specific type)}
435 \twocolitem{4 (VARCHAR)}{REMARKS}
436 \end{twocollist}
437
438 \membersection{wxRecordSet::GetType}
439
440 \func{int}{GetType}{\void}
441
442 Returns the type of the wxRecordSet: wxOPEN\_TYPE\_DYNASET or
443 wxOPEN\_TYPE\_SNAPSHOT. See the wxRecordSet description for details.
444
445 \membersection{wxRecordSet::GoTo}
446
447 \func{bool}{GoTo}{\param{long}{ n}}
448
449 Moves the cursor to the record with the number n, where the first record
450 has the number 0.
451
452 \membersection{wxRecordSet::IsBOF}
453
454 \func{bool}{IsBOF}{\void}
455
456 Returns TRUE if the user tried to move the cursor before the first record
457 in the set.
458
459 \membersection{wxRecordSet::IsFieldDirty}
460
461 \func{bool}{IsFieldDirty}{\param{int}{ field}}
462
463 Returns TRUE if the given field has been changed but not saved yet.
464
465 \func{bool}{IsFieldDirty}{\param{const wxString\& }{name}}
466
467 Same as above, but uses the column name as the identifier.
468
469 \membersection{wxRecordSet::IsFieldNull}
470
471 \func{bool}{IsFieldNull}{\param{int}{ field}}
472
473 Returns TRUE if the given field has no data.
474
475 \func{bool}{IsFieldNull}{\param{const wxString\& }{ name}}
476
477 Same as above, but uses the column name as the identifier.
478
479 \membersection{wxRecordSet::IsColNullable}
480
481 \func{bool}{IsColNullable}{\param{int}{ col}}
482
483 Returns TRUE if the given column may contain no data.
484
485 \func{bool}{IsColNullable}{\param{const wxString\& }{name}}
486
487 Same as above, but uses the column name as the identifier.
488
489 \membersection{wxRecordSet::IsEOF}
490
491 \func{bool}{IsEOF}{\void}
492
493 Returns TRUE if the user tried to move the cursor behind the last record
494 in the set.
495
496 \membersection{wxRecordSet::IsDeleted}
497
498 \func{bool}{IsDeleted}{\void}
499
500 Not implemented.
501
502 \membersection{wxRecordSet::IsOpen}
503
504 \func{bool}{IsOpen}{\void}
505
506 Returns TRUE if the parent database is open.
507
508 \membersection{wxRecordSet::Move}
509
510 \func{bool}{Move}{\param{long}{ rows}}
511
512 Moves the cursor a given number of rows. Negative values are allowed.
513
514 \membersection{wxRecordSet::MoveFirst}
515
516 \func{bool}{MoveFirst}{\void}
517
518 Moves the cursor to the first record.
519
520 \membersection{wxRecordSet::MoveLast}
521
522 \func{bool}{MoveLast}{\void}
523
524 Moves the cursor to the last record.
525
526 \membersection{wxRecordSet::MoveNext}\label{wxrecordsetmovenext}
527
528 \func{bool}{MoveNext}{\void}
529
530 Moves the cursor to the next record.
531
532 \membersection{wxRecordSet::MovePrev}\label{wxrecordsetmoveprev}
533
534 \func{bool}{MovePrev}{\void}
535
536 Moves the cursor to the previous record.
537
538 \membersection{wxRecordSet::Query}
539
540 \func{bool}{Query}{\param{const wxString\& }{columns}, \param{const wxString\& }{table}, \param{const wxString\& }{filter = NULL}}
541
542 Start a query. An SQL string of the following type will automatically be
543 generated and executed: ``SELECT columns FROM table WHERE filter".
544
545 \membersection{wxRecordSet::RecordCountFinal}
546
547 \func{bool}{RecordCountFinal}{\void}
548
549 Not implemented.
550
551 \membersection{wxRecordSet::Requery}
552
553 \func{bool}{Requery}{\void}
554
555 Re-executes the last query. Not implemented.
556
557 \membersection{wxRecordSet::SetFieldDirty}
558
559 \func{void}{SetFieldDirty}{\param{int}{ field}, \param{bool}{ dirty = TRUE}}
560
561 Sets the dirty tag of the field field. Not implemented.
562
563 \func{void}{SetFieldDirty}{\param{const wxString\& }{name}, \param{bool}{ dirty = TRUE}}
564
565 Same as above, but uses the column name as the identifier.
566
567 \membersection{wxRecordSet::SetDefaultSQL}
568
569 \func{void}{SetDefaultSQL}{\param{const wxString\& }{s}}
570
571 Not implemented.
572
573 \membersection{wxRecordSet::SetFieldNull}
574
575 \func{void}{SetFieldNull}{\param{void *}{p}, \param{bool }{isNull = TRUE}}
576
577 Not implemented.
578
579 \membersection{wxRecordSet::SetOptions}
580
581 \func{void}{SetOptions}{\param{int}{ opt}}
582
583 Sets the options of the wxRecordSet. Not implemented.
584
585 \membersection{wxRecordSet::SetTableName}
586
587 \func{void}{SetTableName}{\param{const wxString\& }{tablename}}
588
589 Specify the name of the table you want to use.
590
591 \membersection{wxRecordSet::SetType}
592
593 \func{void}{SetType}{\param{int}{ type}}
594
595 Sets the type of the wxRecordSet. See the wxRecordSet class description for details.
596
597 \membersection{wxRecordSet::Update}
598
599 \func{bool}{Update}{\void}
600
601 Writes back the current record. Not implemented.
602
603