]> git.saurik.com Git - wxWidgets.git/blobdiff - docs/latex/wx/dialup.tex
assert if opening more than one find/replace dialog under the same parent -- this...
[wxWidgets.git] / docs / latex / wx / dialup.tex
index 7c13018ec5d9ef60511067b76133506bdc3c900e..94df86f20c20ce1e0c31a833e3b825df6653ec43 100644 (file)
@@ -11,7 +11,7 @@
 
 \section{\class{wxDialUpManager}}\label{wxdialupmanager}
 
 
 \section{\class{wxDialUpManager}}\label{wxdialupmanager}
 
-This class encapsulates functions dealing with veryfying the connection status
+This class encapsulates functions dealing with verifying the connection status
 of the workstation (connected to the Internet via a direct connection,
 connected through a modem or not connected at all) and to establish this
 connection if possible/required (i.e. in the case of the modem).
 of the workstation (connected to the Internet via a direct connection,
 connected through a modem or not connected at all) and to establish this
 connection if possible/required (i.e. in the case of the modem).
@@ -22,7 +22,7 @@ network the next time or, on the contrary, to stop receiving data from the net
 when the user hangs up the modem). For this, you need to use one of the event
 macros described below.
 
 when the user hangs up the modem). For this, you need to use one of the event
 macros described below.
 
-This class is different from other wxWindows classes in that there is at most
+This class is different from other wxWidgets classes in that there is at most
 one instance of this class in the program accessed via 
 \helpref{wxDialUpManager::Create()}{wxdialupmanagercreate} and you can't
 create the objects of this class directly.
 one instance of this class in the program accessed via 
 \helpref{wxDialUpManager::Create()}{wxdialupmanagercreate} and you can't
 create the objects of this class directly.
@@ -66,8 +66,8 @@ done with it.
 
 \constfunc{bool}{IsOk}{\void}
 
 
 \constfunc{bool}{IsOk}{\void}
 
-Returns {\tt TRUE} if the dialup manager was initialized correctly. If this
-function returns {\tt FALSE}, no other functions will work neither, so it is a
+Returns {\tt true} if the dialup manager was initialized correctly. If this
+function returns {\tt false}, no other functions will work neither, so it is a
 good idea to call this function and check its result before calling any other
 wxDialUpManager methods
 
 good idea to call this function and check its result before calling any other
 wxDialUpManager methods
 
@@ -89,9 +89,9 @@ their number (may be $0$).
 
 \membersection{wxDialUpManager::Dial}\label{wxdialupmanagerdial}
 
 
 \membersection{wxDialUpManager::Dial}\label{wxdialupmanagerdial}
 
-\func{bool}{Dial}{\param{const wxString\& }{nameOfISP = wxEmptyString}, \param{const wxString\& }{username = wxEmptyString}, \param{const wxString\& }{password = wxEmptyString}, \param{bool }{async = TRUE}}
+\func{bool}{Dial}{\param{const wxString\& }{nameOfISP = wxEmptyString}, \param{const wxString\& }{username = wxEmptyString}, \param{const wxString\& }{password = wxEmptyString}, \param{bool }{async = true}}
 
 
-Dial the given ISP, use {\it username} and {\it password} to authentificate.
+Dial the given ISP, use {\it username} and {\it password} to authenticate.
 
 The parameters are only used under Windows currently, for Unix you should use 
 \helpref{SetConnectCommand}{wxdialupmanagersetconnectcommand} to customize this
 
 The parameters are only used under Windows currently, for Unix you should use 
 \helpref{SetConnectCommand}{wxdialupmanagersetconnectcommand} to customize this
@@ -102,10 +102,10 @@ If no {\it nameOfISP} is given, the function will select the default one
 and if no username and/or password are given, the function will try to do
 without them, but will ask the user if really needed.
 
 and if no username and/or password are given, the function will try to do
 without them, but will ask the user if really needed.
 
-If {\it async} parameter is {\tt FALSE}, the function waits until the end of dialing
-and returns {\tt TRUE} upon successful completion.
+If {\it async} parameter is {\tt false}, the function waits until the end of dialing
+and returns {\tt true} upon successful completion.
 
 
-If {\it async} is {\tt TRUE}, the function only initiates the connection and
+If {\it async} is {\tt true}, the function only initiates the connection and
 returns immediately - the result is reported via events (an event is sent
 anyhow, but if dialing failed it will be a DISCONNECTED one).
 
 returns immediately - the result is reported via events (an event is sent
 anyhow, but if dialing failed it will be a DISCONNECTED one).
 
@@ -113,7 +113,7 @@ anyhow, but if dialing failed it will be a DISCONNECTED one).
 
 \constfunc{bool}{IsDialing}{\void}
 
 
 \constfunc{bool}{IsDialing}{\void}
 
-Returns TRUE if (async) dialing is in progress.
+Returns true if (async) dialing is in progress.
 
 \wxheading{See also}
 
 
 \wxheading{See also}
 
@@ -124,7 +124,7 @@ Returns TRUE if (async) dialing is in progress.
 \func{bool}{CancelDialing}{\void}
 
 Cancel dialing the number initiated with \helpref{Dial}{wxdialupmanagerdial} 
 \func{bool}{CancelDialing}{\void}
 
 Cancel dialing the number initiated with \helpref{Dial}{wxdialupmanagerdial} 
-with async parameter equal to {\tt TRUE}.
+with async parameter equal to {\tt true}.
 
 Note that this won't result in DISCONNECTED event being sent.
 
 
 Note that this won't result in DISCONNECTED event being sent.
 
@@ -142,7 +142,7 @@ Hang up the currently active dial up connection.
 
 \constfunc{bool}{IsAlwaysOnline}{\void}
 
 
 \constfunc{bool}{IsAlwaysOnline}{\void}
 
-Returns {\tt TRUE} if the computer has a permanent network connection (i.e. is
+Returns {\tt true} if the computer has a permanent network connection (i.e. is
 on a LAN) and so there is no need to use Dial() function to go online.
 
 {\bf NB:} this functions tries to guess the result and it is not always
 on a LAN) and so there is no need to use Dial() function to go online.
 
 {\bf NB:} this functions tries to guess the result and it is not always
@@ -153,14 +153,14 @@ confirmation or give him a possibility to override it.
 
 \constfunc{bool}{IsOnline}{\void}
 
 
 \constfunc{bool}{IsOnline}{\void}
 
-Returns {\tt TRUE} if the computer is connected to the network: under Windows,
+Returns {\tt true} if the computer is connected to the network: under Windows,
 this just means that a RAS connection exists, under Unix we check that
 the "well-known host" (as specified by 
 \helpref{SetWellKnownHost}{wxdialupmanagersetwellknownhost}) is reachable.
 
 \membersection{wxDialUpManager::SetOnlineStatus}\label{wxdialupmanagersetonlinestatus}
 
 this just means that a RAS connection exists, under Unix we check that
 the "well-known host" (as specified by 
 \helpref{SetWellKnownHost}{wxdialupmanagersetwellknownhost}) is reachable.
 
 \membersection{wxDialUpManager::SetOnlineStatus}\label{wxdialupmanagersetonlinestatus}
 
-\func{void}{SetOnlineStatus}{\param{bool }{isOnline = TRUE}}
+\func{void}{SetOnlineStatus}{\param{bool }{isOnline = true}}
 
 Sometimes the built-in logic for determining the online status may fail,
 so, in general, the user should be allowed to override it. This function
 
 Sometimes the built-in logic for determining the online status may fail,
 so, in general, the user should be allowed to override it. This function
@@ -175,14 +175,14 @@ algorithm may think about it.
 
 \func{bool}{EnableAutoCheckOnlineStatus}{\param{size\_t }{nSeconds = 60}}
 
 
 \func{bool}{EnableAutoCheckOnlineStatus}{\param{size\_t }{nSeconds = 60}}
 
-Enable automatical checks for the connection status and sending of 
+Enable automatic checks for the connection status and sending of 
 {\tt wxEVT\_DIALUP\_CONNECTED/wxEVT\_DIALUP\_DISCONNECTED} events. The interval
 parameter is only for Unix where we do the check manually and specifies how
 often should we repeat the check (each minute by default). Under Windows, the
 notification about the change of connection status is sent by the system and so
 we don't do any polling and this parameter is ignored.
 
 {\tt wxEVT\_DIALUP\_CONNECTED/wxEVT\_DIALUP\_DISCONNECTED} events. The interval
 parameter is only for Unix where we do the check manually and specifies how
 often should we repeat the check (each minute by default). Under Windows, the
 notification about the change of connection status is sent by the system and so
 we don't do any polling and this parameter is ignored.
 
-Returns {\tt FALSE} if couldn't set up automatic check for online status.
+Returns {\tt false} if couldn't set up automatic check for online status.
 
 \membersection{wxDialUpManager::DisableAutoCheckOnlineStatus}\label{wxdialupmanagerdisableautocheckonlinestatus}
 
 
 \membersection{wxDialUpManager::DisableAutoCheckOnlineStatus}\label{wxdialupmanagerdisableautocheckonlinestatus}
 
@@ -203,7 +203,7 @@ is always safe to call. The default value is {\tt www.yahoo.com:80}.
 
 \membersection{wxDialUpManager::SetConnectCommand}\label{wxdialupmanagersetconnectcommand}
 
 
 \membersection{wxDialUpManager::SetConnectCommand}\label{wxdialupmanagersetconnectcommand}
 
-\func{}{SetConnectCommand}{\param{const wxString\& }{commandDial = wxT("/usr/bin/pon")}, \param{const wxString\& }{commandHangup = wxT("/usr/bin/poff")}}
+\func{void}{SetConnectCommand}{\param{const wxString\& }{commandDial = wxT("/usr/bin/pon")}, \param{const wxString\& }{commandHangup = wxT("/usr/bin/poff")}}
 
 This method is for Unix only.
 
 
 This method is for Unix only.