]> git.saurik.com Git - wxWidgets.git/blobdiff - docs/latex/wx/log.tex
Corrected some spacing and typo errors.
[wxWidgets.git] / docs / latex / wx / log.tex
index 6c070e4727805a7d0efdcb7e79c9b035d4062ddc..447d73d2f9e6c1e58c0a49fbde72377b83a9bcc6 100644 (file)
@@ -6,12 +6,12 @@
 %% Created:     some time ago
 %% RCS-ID:      $Id$
 %% Copyright:   (c) 1997-2001 Vadim Zeitlin
-%% License:     wxWindows license
+%% License:     wxWidgets license
 %%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%%
 
 \section{\class{wxLog}}\label{wxlog}
 
-wxLog class defines the interface for the {\it log targets} used by wxWindows
+wxLog class defines the interface for the {\it log targets} used by wxWidgets
 logging functions as explained in the \helpref{wxLog overview}{wxlogoverview}.
 The only situations when you need to directly use this class is when you want
 to derive your own log target because the existing ones don't satisfy your
@@ -23,7 +23,7 @@ completely) the timestamp on the messages.
 Otherwise, it is completely hidden behind the {\it wxLogXXX()} functions and
 you may not even know about its existence.
 
-See \helpref{log overview}{wxlogoverview} for the descriptions of wxWindows
+See \helpref{log overview}{wxlogoverview} for the descriptions of wxWidgets
 logging facilities.
 
 \wxheading{Derived from}
@@ -172,6 +172,7 @@ Add the {\it mask} to the list of allowed masks for
 \helpref{wxLogTrace}{wxlogtrace}.
 
 \wxheading{See also}
+
 \helpref{RemoveTraceMask}{wxlogremovetracemask}
 \helpref{GetTraceMasks}{wxloggettracemasks}
 
@@ -183,6 +184,7 @@ Removes all trace masks previously set with
 \helpref{AddTraceMask}{wxlogaddtracemask}.
 
 \wxheading{See also}
+
 \helpref{RemoveTraceMask}{wxlogremovetracemask}
 
 \membersection{wxLog::GetTraceMasks}\label{wxloggettracemasks}
@@ -192,6 +194,7 @@ Removes all trace masks previously set with
 Returns the currently allowed list of string trace masks.
 
 \wxheading{See also}
+
 \helpref{AddTraceMask}{wxlogaddtracemask}.
 
 \membersection{wxLog::OnLog}\label{wxlogonlog}
@@ -228,7 +231,7 @@ logging immediately without waiting for \helpref{Flush}{wxlogflush} to be
 called (the standard GUI log target only shows the log dialog when it is
 flushed, so Suspend() works as expected with it).
 
-\wxheading{See also:}
+\wxheading{See also}
 
 \helpref{Resume}{wxlogresume},\\
 \helpref{wxLogNull}{wxlogoverview}
@@ -287,7 +290,7 @@ is already empty, nothing happens.
 
 Flushes the current log target if any, does nothing if there is none.
 
-See also:
+\wxheading{See also}
 
 \helpref{Flush}{wxlogflush}
 
@@ -453,9 +456,9 @@ object was created.
 
 \section{\class{wxLogGui}}\label{wxloggui}
 
-This is the default log target for the GUI wxWindows applications. It is passed
+This is the default log target for the GUI wxWidgets applications. It is passed
 to \helpref{wxLog::SetActiveTarget}{wxlogsetactivetarget} at the program
-startup and is deleted by wxWindows during the program shut down.
+startup and is deleted by wxWidgets during the program shut down.
 
 \wxheading{Derived from}
 
@@ -480,7 +483,7 @@ Default constructor.
 This class allows to temporarily suspend logging. All calls to the log
 functions during the life time of an object of this class are just ignored.
 
-In particular, it can be used to suppress the log messages given by wxWindows
+In particular, it can be used to suppress the log messages given by wxWidgets
 itself but it should be noted that it is rarely the best way to cope with this
 problem as {\bf all} log messages are suppressed, even if they indicate a
 completely different error than the one the programmer wanted to suppress.
@@ -500,7 +503,7 @@ For instance, the example of the overview:
 
   wxLogMessage("..."); // ok
 \end{verbatim}
-}
+}%
 
 would be better written as:
 
@@ -520,7 +523,7 @@ would be better written as:
       ...
   }
 \end{verbatim}
-}
+}%
 
 \wxheading{Derived from}
 
@@ -575,7 +578,7 @@ Default ctor installs this object as the current active log target.
 
 This class can be used to redirect the log messages to a C file stream (not to
 be confused with C++ streams). It is the default log target for the non-GUI
-wxWindows applications which send all the output to {\tt stderr}.
+wxWidgets applications which send all the output to {\tt stderr}.
 
 \wxheading{Derived from}
 
@@ -604,7 +607,7 @@ Constructs a log target which sends all the log messages to the given
 
 This class can be used to redirect the log messages to a C++ stream.
 
-Please note that this class is only available if wxWindows was compiled with
+Please note that this class is only available if wxWidgets was compiled with
 the standard iostream library support ({\tt wxUSE\_STD\_IOSTREAM} must be on).
 
 \wxheading{Derived from}
@@ -724,7 +727,7 @@ any extra initializations.
 
 \membersection{wxLogWindow::OnFrameClose}\label{wxlogwindowonframeclose}
 
-\func{virtual void}{OnFrameClose}{\param{wxFrame }{*frame}}
+\func{virtual bool}{OnFrameClose}{\param{wxFrame }{*frame}}
 
 Called if the user closes the window interactively, will not be
 called if it is destroyed for another reason (such as when program