-/********** wxTable::bindInsertParams() **********/
-bool wxTable::bindInsertParams(void)
-{
- SWORD fSqlType;
- UDWORD precision;
- SWORD scale;
-
-//glt CcolDef *tColDef;
-
- // Bind each column (that can be inserted) of the table to a parameter marker
- for (int i = 0; i < noCols; i++)
- {
-//glt tColDef = &colDefs[i];
- if (! colDefs[i].InsertAllowed)
- continue;
- switch(colDefs[i].DbDataType)
- {
- case DB_DATA_TYPE_VARCHAR:
- fSqlType = pDb->typeInfVarchar.FsqlType;
- precision = colDefs[i].SzDataObj;
- scale = 0;
- colDefs[i].CbValue = SQL_NTS;
- break;
- case DB_DATA_TYPE_INTEGER:
- fSqlType = pDb->typeInfInteger.FsqlType;
- precision = pDb->typeInfInteger.Precision;
- scale = 0;
- colDefs[i].CbValue = 0;
- break;
- case DB_DATA_TYPE_FLOAT:
- fSqlType = pDb->typeInfFloat.FsqlType;
- precision = pDb->typeInfFloat.Precision;
- scale = pDb->typeInfFloat.MaximumScale;
- // SQL Sybase Anywhere v5.5 returned a negative number for the
- // MaxScale. This caused ODBC to kick out an error on ibscale.
- // I check for this here and set the scale = precision.
- //if (scale < 0)
- // scale = (short) precision;
- colDefs[i].CbValue = 0;
- break;
- case DB_DATA_TYPE_DATE:
- fSqlType = pDb->typeInfDate.FsqlType;
- precision = pDb->typeInfDate.Precision;
- scale = 0;
- colDefs[i].CbValue = 0;
- break;
- }
- if (SQLBindParameter(hstmtInsert, i+1, SQL_PARAM_INPUT, colDefs[i].SqlCtype,
- fSqlType, precision, scale, colDefs[i].PtrDataObj,
- precision+1,&colDefs[i].CbValue) != SQL_SUCCESS)
- return(pDb->DispAllErrors(henv, hdbc, hstmtInsert));
- }
-
- // Completed successfully
- return(TRUE);
-
-} // wxTable::bindInsertParams()
-
-/********** wxTable::bindUpdateParams() **********/
-bool wxTable::bindUpdateParams(void)
-{
- SWORD fSqlType;
- UDWORD precision;
- SWORD scale;
-
- // Bind each UPDATEABLE column of the table to a parameter marker
- for (int i = 0, colNo = 1; i < noCols; i++)
- {
- if (! colDefs[i].Updateable)
- continue;
- switch(colDefs[i].DbDataType)
- {
- case DB_DATA_TYPE_VARCHAR:
- fSqlType = pDb->typeInfVarchar.FsqlType;
- precision = colDefs[i].SzDataObj;
- scale = 0;
- colDefs[i].CbValue = SQL_NTS;
- break;
- case DB_DATA_TYPE_INTEGER:
- fSqlType = pDb->typeInfInteger.FsqlType;
- precision = pDb->typeInfInteger.Precision;
- scale = 0;
- colDefs[i].CbValue = 0;
- break;
- case DB_DATA_TYPE_FLOAT:
- fSqlType = pDb->typeInfFloat.FsqlType;
- precision = pDb->typeInfFloat.Precision;
- scale = pDb->typeInfFloat.MaximumScale;
- // SQL Sybase Anywhere v5.5 returned a negative number for the
- // MaxScale. This caused ODBC to kick out an error on ibscale.
- // I check for this here and set the scale = precision.
- //if (scale < 0)
- // scale = (short) precision;
- colDefs[i].CbValue = 0;
- break;
- case DB_DATA_TYPE_DATE:
- fSqlType = pDb->typeInfDate.FsqlType;
- precision = pDb->typeInfDate.Precision;
- scale = 0;
- colDefs[i].CbValue = 0;
- break;
- }
- if (SQLBindParameter(hstmtUpdate, colNo++, SQL_PARAM_INPUT, colDefs[i].SqlCtype,
- fSqlType, precision, scale, colDefs[i].PtrDataObj,
- precision+1, &colDefs[i].CbValue) != SQL_SUCCESS)
- return(pDb->DispAllErrors(henv, hdbc, hstmtUpdate));
- }
-
- // Completed successfully
- return(TRUE);
-
-} // wxTable::bindUpdateParams()
-
-/********** wxTable::bindCols() **********/
-bool wxTable::bindCols(HSTMT cursor)
-{
- static SDWORD cb;
-
- // Bind each column of the table to a memory address for fetching data
- for (int i = 0; i < noCols; i++)
- {
- if (SQLBindCol(cursor, i+1, colDefs[i].SqlCtype, colDefs[i].PtrDataObj,
- colDefs[i].SzDataObj, &cb) != SQL_SUCCESS)
- return(pDb->DispAllErrors(henv, hdbc, cursor));
- }
-
- // Completed successfully
- return(TRUE);
-
-} // wxTable::bindCols()
-
-/********** wxTable::CloseCursor() **********/
-bool wxTable::CloseCursor(HSTMT cursor)