__FREE_ZONE
__MALLOC
__MALLOC_ZONE
-_bpfattach
_bcd2bin_data
_bdevsw_add
_bdevsw_isfree
_bdevsw_remove
+_bpf_attach
+_bpf_tap_in
+_bpf_tap_out
+_bpfattach
_bsd_timeout
_bsd_untimeout
_buf_alloc
_buf_error
_buf_flags
_buf_flushdirtyblks
+_buf_fua
_buf_free
_buf_fsprivate
_buf_fromcache
_buf_markaged
_buf_markdelayed
_buf_markeintr
+_buf_markfua
_buf_markinvalid
_buf_meta_bread
_buf_meta_breadn
_cluster_bp
_cluster_copy_ubc_data
_cluster_copy_upl_data
+_advisory_read
_cluster_pagein
_cluster_pageout
_cluster_push
_cluster_read
_cluster_write
+_cluster_bp_ext
+_advisory_read_ext
+_cluster_pagein_ext
+_cluster_pageout_ext
+_cluster_push_ext
+_cluster_read_ext
+_cluster_write_ext
_cluster_zero
_copystr
_ctl_deregister
_current_proc
_desiredvnodes
_devfs_make_node
+_devfs_make_node_clone
_devfs_remove
_enodev
_enodev_strat
_err_close
_err_copyfile
_err_create
-_err_devblocksize
_err_exchange
_err_fsync
_err_getattr
-_err_getattrlist
_err_inactive
_err_ioctl
_err_link
_err_searchfs
_err_select
_err_setattr
-_err_setattrlist
_err_strategy
_err_symlink
_err_whiteout
_ifnet_output_raw
_ifnet_reference
_ifnet_release
+_ifnet_resolve_multicast:_dlil_resolve_multi
_ifnet_remove_multicast
_ifnet_set_addrlen
_ifnet_set_baudrate
_ifnet_type
_ifnet_unit
_iftovt_tab
+_in_cksum:_inet_cksum_simple
_inet_arp_handle_input:_arp_ip_handle_input
_inet_arp_init_ifaddr:_arp_ifinit
_inet_arp_lookup:_arp_lookup_ip
_kauth_cred_rele
_kauth_cred_uid2guid
_kauth_cred_uid2ntsid
+_kauth_cred_unref
_kauth_deregister_scope
_kauth_getgid
_kauth_getruid
_ldisc_register
_lightning_bolt
_mbuf_adj
-_mbuf_allocpacket
+_mbuf_adjustlen
_mbuf_align_32
-_mbuf_aux_add
-_mbuf_aux_delete
-_mbuf_aux_find
+_mbuf_alloccluster
+_mbuf_allocpacket
+_mbuf_allocpacket_list
+_mbuf_attachcluster
_mbuf_clear_csum_performed
_mbuf_clear_csum_requested
_mbuf_clear_vlan_tag
_mbuf_copyback
_mbuf_copydata
_mbuf_copym
-_mbuf_data
_mbuf_data_to_physical
_mbuf_datastart
_mbuf_dup
_mbuf_flags
_mbuf_free
+_mbuf_freecluster
_mbuf_freem
_mbuf_freem_list
_mbuf_get
-_mbuf_getcluster
_mbuf_get_csum_performed
_mbuf_get_csum_requested
_mbuf_get_vlan_tag
+_mbuf_getcluster
_mbuf_gethdr
_mbuf_getpacket
_mbuf_inbound_modified
+_mbuf_inet_cksum
_mbuf_leadingspace
-_mbuf_len
_mbuf_maxlen
_mbuf_mclget
_mbuf_mclhasreference
-_mbuf_next
-_mbuf_nextpkt
_mbuf_outbound_finalize
-_mbuf_pkthdr_header
-_mbuf_pkthdr_len
-_mbuf_pkthdr_rcvif
-_mbuf_pkthdr_setheader
+_mbuf_pkthdr_adjustlen
_mbuf_pkthdr_setlen
_mbuf_pkthdr_setrcvif
_mbuf_prepend
_mbuf_setdata
_mbuf_setflags
_mbuf_setflags_mask
-_mbuf_setlen
_mbuf_setnext
-_mbuf_setnextpkt
_mbuf_settype
_mbuf_split
_mbuf_stats
_mbuf_tag_allocate
_mbuf_tag_find
-_mbuf_tag_id_find
_mbuf_tag_free
+_mbuf_tag_id_find
_mbuf_trailingspace
-_mbuf_type
_microtime
_microuptime
_minphys
_msleep
_nanotime
_nanouptime
-_nd6_lookup_ipv6
_net_init_add
_nop_access
_nop_advlock
_nop_close
_nop_copyfile
_nop_create
-_nop_devblocksize
_nop_exchange
_nop_fsync
_nop_getattr
-_nop_getattrlist
_nop_inactive
_nop_ioctl
_nop_link
_nop_searchfs
_nop_select
_nop_setattr
-_nop_setattrlist
_nop_strategy
_nop_symlink
_nop_whiteout
_nullop
_physio
_postevent
+_proc_exiting
_proc_find
_proc_forcequota
_proc_is64bit
_sflt_detach
_sflt_register
_sflt_unregister
-_snprintf
_sock_accept
_sock_bind
_sock_close
_ubc_info_init
_ubc_info_zone
_ubc_isinuse
+_ubc_msync
_ubc_offtoblk
_ubc_page_op
+_ubc_pages_resident
_ubc_range_op
_ubc_setcred
_ubc_setsize
+_ubc_setthreadcred
_ubc_sync_range
_ubc_upl_abort
_ubc_upl_abort_range
_ubc_upl_commit
_ubc_upl_commit_range
_ubc_upl_map
+_ubc_upl_maxbufsize
_ubc_upl_unmap
_ubc_upl_pageinfo
_upl_page_present
_uiomove64
_useracc
_utf8_decodestr
+_utf8_encodelen
_utf8_encodestr
+_utf8_normalizestr
_utf8_validatestr
_vcount
_vflush
_vfs_64bitready
_vfs_addname
+_vfs_authcache_ttl
_vfs_authopaque
_vfs_authopaqueaccess
_vfs_busy
+_vfs_clearauthcache_ttl
_vfs_clearauthopaque
_vfs_clearauthopaqueaccess
_vfs_clearextendedsecurity
_vfs_opv_init
_vfs_opv_numops
_vfs_removename
+_vfs_setauthcache_ttl
_vfs_setauthopaque
_vfs_setauthopaqueaccess
_vfs_setextendedsecurity
_vfs_sysctl
_vfs_typenum
_vfs_unbusy
-_vn_access
+_vfs_unmountbyfsid
_vn_bwrite
_vn_default_error
_vn_getpath
+_vn_path_package_check
_vn_rdwr
_vn_revoke
_vnode_addfsref
_vnode_removefsref
_vnode_setattr
_vnode_setmountedon
+_vnode_setmultipath
_vnode_setnocache
_vnode_setnoreadahead
_vnode_settag
_vnode_specrdev
_vnode_startwrite
+_vnode_uncache_credentials
_vnode_vfs64bitready
_vnode_vfsisrdonly
_vnode_vfsmaxsymlen
_vnop_exchange_desc
_vnop_fsync_desc
_vnop_getattr_desc
-_vnop_getattrlist_desc
_vnop_getxattr_desc
_vnop_inactive_desc
_vnop_ioctl_desc
_vnop_searchfs_desc
_vnop_select_desc
_vnop_setattr_desc
-_vnop_setattrlist_desc
_vnop_setxattr_desc
_vnop_strategy_desc
_vnop_symlink_desc