]>
Commit | Line | Data |
---|---|---|
b7080c8e A |
1 | .\" Copyright (c) 1990, 1991, 1993 |
2 | .\" The Regents of the University of California. All rights reserved. | |
3 | .\" | |
4 | .\" Redistribution and use in source and binary forms, with or without | |
5 | .\" modification, are permitted provided that the following conditions | |
6 | .\" are met: | |
7 | .\" 1. Redistributions of source code must retain the above copyright | |
8 | .\" notice, this list of conditions and the following disclaimer. | |
9 | .\" 2. Redistributions in binary form must reproduce the above copyright | |
10 | .\" notice, this list of conditions and the following disclaimer in the | |
11 | .\" documentation and/or other materials provided with the distribution. | |
12 | .\" 3. All advertising materials mentioning features or use of this software | |
13 | .\" must display the following acknowledgement: | |
14 | .\" This product includes software developed by the University of | |
15 | .\" California, Berkeley and its contributors. | |
16 | .\" 4. Neither the name of the University nor the names of its contributors | |
17 | .\" may be used to endorse or promote products derived from this software | |
18 | .\" without specific prior written permission. | |
19 | .\" | |
20 | .\" THIS SOFTWARE IS PROVIDED BY THE REGENTS AND CONTRIBUTORS ``AS IS'' AND | |
21 | .\" ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO, THE | |
22 | .\" IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE | |
23 | .\" ARE DISCLAIMED. IN NO EVENT SHALL THE REGENTS OR CONTRIBUTORS BE LIABLE | |
24 | .\" FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL | |
25 | .\" DAMAGES (INCLUDING, BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS | |
26 | .\" OR SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) | |
27 | .\" HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT | |
28 | .\" LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY | |
29 | .\" OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF | |
30 | .\" SUCH DAMAGE. | |
31 | .\" | |
32 | .\" @(#)startslip.1 8.1 (Berkeley) 6/5/93 | |
33 | .\" | |
34 | .Dd June 5, 1993 | |
35 | .Dt STARTSLIP 1 | |
36 | .Os BSD 4.4 | |
37 | .Sh NAME | |
38 | .Nm startslip | |
39 | .Nd dial up and login to a slip server | |
40 | .Sh SYNOPSIS | |
41 | .Nm startslip | |
42 | .Op Fl d | |
43 | .Op Fl s Ar string | |
44 | .Op Fl A Ar annexname | |
45 | .Op Fl F Ar flowcontrol | |
46 | .Ar device user passwd | |
47 | .Sh DESCRIPTION | |
48 | .Nm Startslip | |
49 | opens the specified | |
50 | .Ar device . | |
51 | .Pp | |
52 | Once carrier is asserted | |
53 | .Nm startslip | |
54 | attempts to login as the specified | |
55 | .Ar user | |
56 | with the given | |
57 | .Ar password . | |
58 | If successful, it puts the device into the slip line discipline. | |
59 | If carrier drops and a | |
60 | .Dv SIGHUP | |
61 | is sent to | |
62 | .Nm startslip , | |
63 | it closes the device and attempts to repeat the dialup and login sequence. | |
64 | .Pp | |
65 | Available options: | |
66 | .Bl -tag -width Ar | |
67 | .It Fl d | |
68 | .Nm Startslip | |
69 | prints out debugging information about what it is trying to do. | |
70 | .It Fl s Ar string | |
71 | The optional | |
72 | .Ar string | |
73 | is written to | |
74 | .Ar device . | |
75 | For a dialup modem, | |
76 | the string is used to specify a dial sequence. | |
77 | .It Fl A Ar annexname | |
78 | .Nm Startslip | |
79 | assumes it is connecting to a Xylogics Annex box and engages in an | |
80 | appropriate dialog using the | |
81 | .Ar user | |
82 | and | |
83 | .Ar passwd | |
84 | arguments. | |
85 | The | |
86 | .Ar annexname | |
87 | argument is a string that is used to match against the Annex prompt | |
88 | to determine when a connection has been established. | |
89 | .It Fl F Ar flowcontrol | |
90 | Determines the type of flow control used on | |
91 | .Ar device . | |
92 | Choices for | |
93 | .Ar flowcontrol | |
94 | are | |
95 | ``none'' for no flow control (the default), | |
96 | ``hw'' for hardware RTS/CTS flow control and | |
97 | ``sw'' for software XON/XOFF flow control. | |
98 | .El | |
99 | .Sh SEE ALSO | |
100 | .Xr sliplogin 8 | |
101 | .Sh HISTORY | |
102 | The | |
103 | .Nm startslip | |
104 | appeared in | |
105 | .Bx 4.4 . |