From b54ceb72ce8d03400f6f002c8bec3fa27b6c32f5 Mon Sep 17 00:00:00 2001 From: Vadim Zeitlin Date: Thu, 9 Sep 2010 21:49:25 +0000 Subject: [PATCH] Remember last values used in exec sample "Kill" menu item dialogs. Remember the PID entered in the dialog and also remember the last used signal number. This makes these dialogs slightly less painful to use when testing even though ideally we'd have a single dialog for choosing both values instead of two consecutive modal dialogs. git-svn-id: https://svn.wxwidgets.org/svn/wx/wxWidgets/trunk@65492 c3d73ce0-8a6f-49c7-b76d-6d57e0e08775 --- samples/exec/exec.cpp | 9 ++++++++- 1 file changed, 8 insertions(+), 1 deletion(-) diff --git a/samples/exec/exec.cpp b/samples/exec/exec.cpp index d5c0e4f181..fcbe8b3029 100644 --- a/samples/exec/exec.cpp +++ b/samples/exec/exec.cpp @@ -571,6 +571,8 @@ void MyFrame::OnKill(wxCommandEvent& WXUNUSED(event)) return; } + m_pidLast = pid; + static const wxString signalNames[] = { wxT("Just test (SIGNONE)"), @@ -591,9 +593,11 @@ void MyFrame::OnKill(wxCommandEvent& WXUNUSED(event)) wxT("Terminate (SIGTERM)"), }; + static int s_sigLast = wxSIGNONE; int sig = wxGetSingleChoiceIndex(wxT("How to kill the process?"), wxT("Exec question"), WXSIZEOF(signalNames), signalNames, + s_sigLast, this); switch ( sig ) { @@ -624,8 +628,11 @@ void MyFrame::OnKill(wxCommandEvent& WXUNUSED(event)) break; } - if ( sig == 0 ) + s_sigLast = sig; + + if ( sig == wxSIGNONE ) { + // This simply calls Kill(wxSIGNONE) but using it is more convenient. if ( wxProcess::Exists(pid) ) { wxLogStatus(wxT("Process %ld is running."), pid); -- 2.45.2