From 6222ad281a69bce12d71fa1cdd912872070d7908 Mon Sep 17 00:00:00 2001 From: Vadim Zeitlin Date: Mon, 4 Oct 2010 10:41:44 +0000 Subject: [PATCH] Fix timing format string in the test suite. wxStopWatch::Time() returns a long value so use %ld, not %d. This fixes assert failure when using "-t" option with the test suite under 64 bit Unix architectures. git-svn-id: https://svn.wxwidgets.org/svn/wx/wxWidgets/trunk@65759 c3d73ce0-8a6f-49c7-b76d-6d57e0e08775 --- tests/test.cpp | 2 +- 1 file changed, 1 insertion(+), 1 deletion(-) diff --git a/tests/test.cpp b/tests/test.cpp index a8208adb1a..1e59f59806 100644 --- a/tests/test.cpp +++ b/tests/test.cpp @@ -209,7 +209,7 @@ public: m_watch.Pause(); wxPrintf(GetResultStr(m_result)); if (m_timing) - wxPrintf(" %6d ms", m_watch.Time()); + wxPrintf(" %6ld ms", m_watch.Time()); wxPrintf("\n"); } -- 2.45.2