X-Git-Url: https://git.saurik.com/wxWidgets.git/blobdiff_plain/232addd1cd1515d08ab48335f14f6156363efb82..7a7fa93b0dd56b06325740cebc91f1156c18e30c:/include/wx/log.h diff --git a/include/wx/log.h b/include/wx/log.h index e3626ad634..90dde5e6b4 100644 --- a/include/wx/log.h +++ b/include/wx/log.h @@ -29,7 +29,7 @@ typedef unsigned long wxLogLevel; #define wxTraceResAlloc 0x0004 // trace GDI resource allocation #define wxTraceRefCount 0x0008 // trace various ref counting operations - #ifdef __WXMSW__ + #ifdef __WINDOWS__ #define wxTraceOleCalls 0x0100 // OLE interface calls #endif @@ -43,15 +43,23 @@ typedef unsigned long wxLogLevel; #include "wx/string.h" #include "wx/strvararg.h" +// ---------------------------------------------------------------------------- +// forward declarations +// ---------------------------------------------------------------------------- + +class WXDLLIMPEXP_FWD_BASE wxObject; + +#if wxUSE_GUI + class WXDLLIMPEXP_FWD_CORE wxFrame; +#endif // wxUSE_GUI + #if wxUSE_LOG #include "wx/arrstr.h" -#ifndef __WXPALMOS5__ #ifndef __WXWINCE__ #include // for time_t #endif -#endif // ! __WXPALMOS5__ #include "wx/dynarray.h" #include "wx/hashmap.h" @@ -91,16 +99,6 @@ typedef unsigned long wxLogLevel; #endif #endif -// ---------------------------------------------------------------------------- -// forward declarations -// ---------------------------------------------------------------------------- - -class WXDLLIMPEXP_FWD_BASE wxObject; - -#if wxUSE_GUI - class WXDLLIMPEXP_FWD_CORE wxFrame; -#endif // wxUSE_GUI - // ---------------------------------------------------------------------------- // constants // ---------------------------------------------------------------------------- @@ -130,7 +128,7 @@ enum wxLogLevelValues #define wxTRACE_ResAlloc wxT("resalloc") // trace GDI resource allocation #define wxTRACE_RefCount wxT("refcount") // trace various ref counting operations -#ifdef __WXMSW__ +#ifdef __WINDOWS__ #define wxTRACE_OleCalls wxT("ole") // OLE interface calls #endif @@ -309,6 +307,34 @@ struct wxLogRecord wxLogRecordInfo info; }; +// ---------------------------------------------------------------------------- +// Derive from this class to customize format of log messages. +// ---------------------------------------------------------------------------- + +class WXDLLIMPEXP_BASE wxLogFormatter +{ +public: + // Default constructor. + wxLogFormatter() { } + + // Trivial but virtual destructor for the base class. + virtual ~wxLogFormatter() { } + + + // Override this method to implement custom formatting of the given log + // record. The default implementation simply prepends a level-dependent + // prefix to the message and optionally adds a time stamp. + virtual wxString Format(wxLogLevel level, + const wxString& msg, + const wxLogRecordInfo& info) const; + +protected: + // Override this method to change just the time stamp formatting. It is + // called by default Format() implementation. + virtual wxString FormatTime(time_t t) const; +}; + + // ---------------------------------------------------------------------------- // derive from this class to redirect (or suppress, or ...) log messages // normally, only a single instance of this class exists but it's not enforced @@ -318,7 +344,7 @@ class WXDLLIMPEXP_BASE wxLog { public: // ctor - wxLog() { } + wxLog() : m_formatter(new wxLogFormatter) { } // make dtor virtual for all derived classes virtual ~wxLog(); @@ -328,15 +354,32 @@ public: // ---------------------- // these functions allow to completely disable all log messages or disable - // log messages at level less important than specified + // log messages at level less important than specified for the current + // thread // is logging enabled at all now? - static bool IsEnabled() { return ms_doLog; } + static bool IsEnabled() + { +#if wxUSE_THREADS + if ( !wxThread::IsMain() ) + return IsThreadLoggingEnabled(); +#endif // wxUSE_THREADS + + return ms_doLog; + } // change the flag state, return the previous one - static bool EnableLogging(bool doIt = true) - { bool doLogOld = ms_doLog; ms_doLog = doIt; return doLogOld; } + static bool EnableLogging(bool enable = true) + { +#if wxUSE_THREADS + if ( !wxThread::IsMain() ) + return EnableThreadLogging(enable); +#endif // wxUSE_THREADS + bool doLogOld = ms_doLog; + ms_doLog = enable; + return doLogOld; + } // return the current global log level static wxLogLevel GetLogLevel() { return ms_logLevel; } @@ -381,28 +424,26 @@ public: // ----------------- // flush shows all messages if they're not logged immediately (FILE - // and iostream logs don't need it, but wxGuiLog does to avoid showing + // and iostream logs don't need it, but wxLogGui does to avoid showing // 17 modal dialogs one after another) virtual void Flush(); - // flush the active target if any - static void FlushActive() - { - if ( !ms_suspendCount ) - { - wxLog *log = GetActiveTarget(); - if ( log ) - log->Flush(); - } - } + // flush the active target if any and also output any pending messages from + // background threads + static void FlushActive(); - // only one sink is active at each moment - // get current log target, will call wxApp::CreateLogTarget() to - // create one if none exists + // only one sink is active at each moment get current log target, will call + // wxAppTraits::CreateLogTarget() to create one if none exists static wxLog *GetActiveTarget(); - // change log target, pLogger may be NULL - static wxLog *SetActiveTarget(wxLog *pLogger); + // change log target, logger may be NULL + static wxLog *SetActiveTarget(wxLog *logger); + +#if wxUSE_THREADS + // change log target for the current thread only, shouldn't be called from + // the main thread as it doesn't use thread-specific log target + static wxLog *SetThreadActiveTarget(wxLog *logger); +#endif // wxUSE_THREADS // suspend the message flushing of the main target until the next call // to Resume() - this is mainly for internal use (to prevent wxYield() @@ -438,7 +479,27 @@ public: // get string trace masks: note that this is MT-unsafe if other threads can // call AddTraceMask() concurrently - static const wxArrayString& GetTraceMasks() { return ms_aTraceMasks; } + static const wxArrayString& GetTraceMasks(); + + // is this trace mask in the list? + static bool IsAllowedTraceMask(const wxString& mask); + + + // log formatting + // ----------------- + + // Change wxLogFormatter object used by wxLog to format the log messages. + // + // wxLog takes ownership of the pointer passed in but the caller is + // responsible for deleting the returned pointer. + wxLogFormatter* SetFormatter(wxLogFormatter* formatter); + + + // All the time stamp related functions below only work when the default + // wxLogFormatter is being used. Defining a custom formatter overrides them + // as it could use its own time stamp format or format messages without + // using time stamp at all. + // sets the time stamp string format: this is used as strftime() format // string for the log targets which add time stamps to the messages; set @@ -449,9 +510,6 @@ public: static void DisableTimestamp() { SetTimestamp(wxEmptyString); } - // is this trace mask in the list? - static bool IsAllowedTraceMask(const wxString& mask); - // get the current timestamp format string (maybe empty) static const wxString& GetTimestamp() { return ms_timestamp; } @@ -460,9 +518,10 @@ public: // helpers: all functions in this section are mostly for internal use only, // don't call them from your code even if they are not formally deprecated - // put the time stamp into the string if ms_timestamp != NULL (don't - // change it otherwise) + // put the time stamp into the string if ms_timestamp is not empty (don't + // change it otherwise); the first overload uses the current time. static void TimeStamp(wxString *str); + static void TimeStamp(wxString *str, time_t t); // these methods should only be called from derived classes DoLogRecord(), // DoLogTextAtLevel() and DoLogText() implementations respectively and @@ -507,14 +566,14 @@ public: #if WXWIN_COMPATIBILITY_2_6 // this function doesn't do anything any more, don't call it - wxDEPRECATED_INLINE( - static wxChar *SetLogBuffer(wxChar *, size_t = 0), return NULL; + static wxDEPRECATED_INLINE( + wxChar *SetLogBuffer(wxChar *, size_t = 0), return NULL; ); #endif // WXWIN_COMPATIBILITY_2_6 // don't use integer masks any more, use string trace masks instead #if WXWIN_COMPATIBILITY_2_8 - wxDEPRECATED_INLINE( static void SetTraceMask(wxTraceMask ulMask), + static wxDEPRECATED_INLINE( void SetTraceMask(wxTraceMask ulMask), ms_ulTraceMask = ulMask; ) // this one can't be marked deprecated as it's used in our own wxLogger @@ -580,15 +639,36 @@ protected: unsigned LogLastRepeatIfNeeded(); private: - // implement of LogLastRepeatIfNeeded(): it assumes that the - // caller had already locked GetPreviousLogCS() - unsigned LogLastRepeatIfNeededUnlocked(); +#if wxUSE_THREADS + // called from FlushActive() to really log any buffered messages logged + // from the other threads + void FlushThreadMessages(); + + // these functions are called for non-main thread only by IsEnabled() and + // EnableLogging() respectively + static bool IsThreadLoggingEnabled(); + static bool EnableThreadLogging(bool enable = true); +#endif // wxUSE_THREADS + + // get the active log target for the main thread, auto-creating it if + // necessary + // + // this is called from GetActiveTarget() and OnLog() when they're called + // from the main thread + static wxLog *GetMainThreadActiveTarget(); - // called from OnLog() if it's called from the main thread and from Flush() + // called from OnLog() if it's called from the main thread or if we have a + // (presumably MT-safe) thread-specific logger and by FlushThreadMessages() // when it plays back the buffered messages logged from the other threads - void OnLogInMainThread(wxLogLevel level, - const wxString& msg, - const wxLogRecordInfo& info); + void CallDoLogNow(wxLogLevel level, + const wxString& msg, + const wxLogRecordInfo& info); + + + // variables + // ---------------- + + wxLogFormatter *m_formatter; // We own this pointer. // static variables @@ -614,9 +694,6 @@ private: #if WXWIN_COMPATIBILITY_2_8 static wxTraceMask ms_ulTraceMask; // controls wxLogTrace behaviour #endif // WXWIN_COMPATIBILITY_2_8 - - // currently enabled trace masks - static wxArrayString ms_aTraceMasks; }; // ---------------------------------------------------------------------------- @@ -833,12 +910,12 @@ public: // indicates that we may have an extra first argument preceding the format // string and that if we do have it, we should store it in m_info using the // given key (while by default 0 value will be used) - wxLogger& MaybeStore(const wxString& key) + wxLogger& MaybeStore(const wxString& key, wxUIntPtr value = 0) { wxASSERT_MSG( m_optKey.empty(), "can only have one optional value" ); m_optKey = key; - m_info.StoreValue(key, 0); + m_info.StoreValue(key, value); return *this; } @@ -871,6 +948,16 @@ public: LogV(format, argptr); } + void LogVTrace(const wxString& mask, const wxString& format, va_list argptr) + { + if ( !wxLog::IsAllowedTraceMask(mask) ) + return; + + Store(wxLOG_KEY_TRACE_MASK, mask); + + LogV(format, argptr); + } + // vararg functions used by wxLogXXX(): @@ -1167,7 +1254,7 @@ private: void DoCallOnLog(const wxString& format, va_list argptr) { - wxLog::OnLog(m_level, wxString::FormatV(format, argptr), m_info); + DoCallOnLog(m_level, format, argptr); } @@ -1267,7 +1354,7 @@ WXDLLIMPEXP_BASE const wxChar* wxSysErrorMsg(unsigned long nErrCode = 0); wxDO_LOG(level) // wxLogFatalError() is special as it can't be disabled -#define wxLogFatalError wxDO_LOG(FatalError) +#define wxLogFatalError wxDO_LOG(FatalError) #define wxVLogFatalError(format, argptr) wxDO_LOGV(FatalError, format, argptr) #define wxLogError wxDO_LOG_IF_ENABLED(Error) @@ -1314,19 +1401,30 @@ WXDLLIMPEXP_BASE const wxChar* wxSysErrorMsg(unsigned long nErrCode = 0); // wxLogSysError() needs to stash the error code value in the log record info // so it needs special handling too; additional complications arise because the // error code may or not be present as the first argument +// +// notice that we unfortunately can't avoid the call to wxSysErrorCode() even +// though it may be unneeded if an explicit error code is passed to us because +// the message might not be logged immediately (e.g. it could be queued for +// logging from the main thread later) and so we can't to wait until it is +// logged to determine whether we have last error or not as it will be too late +// and it will have changed already by then (in fact it even changes when +// wxString::Format() is called because of vsnprintf() inside it so it can +// change even much sooner) #define wxLOG_KEY_SYS_ERROR_CODE "wx.sys_error" #define wxLogSysError \ if ( !wxLog::IsLevelEnabled(wxLOG_Error, wxLOG_COMPONENT) ) \ {} \ else \ - wxMAKE_LOGGER(Error).MaybeStore(wxLOG_KEY_SYS_ERROR_CODE).Log + wxMAKE_LOGGER(Error).MaybeStore(wxLOG_KEY_SYS_ERROR_CODE, \ + wxSysErrorCode()).Log // unfortunately we can't have overloaded macros so we can't define versions // both with and without error code argument and have to rely on LogV() // overloads in wxLogger to select between them #define wxVLogSysError \ - wxMAKE_LOGGER(Error).MaybeStore(wxLOG_KEY_SYS_ERROR_CODE).LogV + wxMAKE_LOGGER(Error).MaybeStore(wxLOG_KEY_SYS_ERROR_CODE, \ + wxSysErrorCode()).LogV #if wxUSE_GUI // wxLogStatus() is similar to wxLogSysError() as it allows to optionally @@ -1364,24 +1462,24 @@ WXDLLIMPEXP_BASE const wxChar* wxSysErrorMsg(unsigned long nErrCode = 0); // WX_WATCOM_ONLY_CODE is needed to work around // http://bugzilla.openwatcom.org/show_bug.cgi?id=351 #define wxDEFINE_EMPTY_LOG_FUNCTION(level) \ - WX_DEFINE_VARARG_FUNC_NOP(wxLog##level, 1, (const wxString&)) \ + WX_DEFINE_VARARG_FUNC_NOP(wxLog##level, 1, (const wxFormatString&)) \ WX_WATCOM_ONLY_CODE( \ WX_DEFINE_VARARG_FUNC_NOP(wxLog##level, 1, (const char*)) \ WX_DEFINE_VARARG_FUNC_NOP(wxLog##level, 1, (const wchar_t*)) \ WX_DEFINE_VARARG_FUNC_NOP(wxLog##level, 1, (const wxCStrData&)) \ ) \ - inline void wxVLog##level(const wxString& WXUNUSED(format), \ + inline void wxVLog##level(const wxFormatString& WXUNUSED(format), \ va_list WXUNUSED(argptr)) { } \ #define wxDEFINE_EMPTY_LOG_FUNCTION2(level, argclass) \ - WX_DEFINE_VARARG_FUNC_NOP(wxLog##level, 2, (argclass, const wxString&)) \ + WX_DEFINE_VARARG_FUNC_NOP(wxLog##level, 2, (argclass, const wxFormatString&)) \ WX_WATCOM_OR_MINGW_ONLY_CODE( \ WX_DEFINE_VARARG_FUNC_NOP(wxLog##level, 2, (argclass, const char*)) \ WX_DEFINE_VARARG_FUNC_NOP(wxLog##level, 2, (argclass, const wchar_t*)) \ WX_DEFINE_VARARG_FUNC_NOP(wxLog##level, 2, (argclass, const wxCStrData&)) \ ) \ inline void wxVLog##level(argclass WXUNUSED(arg), \ - const wxString& WXUNUSED(format), \ + const wxFormatString& WXUNUSED(format), \ va_list WXUNUSED(argptr)) {} wxDEFINE_EMPTY_LOG_FUNCTION(FatalError); @@ -1448,7 +1546,7 @@ public: #ifdef HAVE_VARIADIC_MACROS #define wxLogDebug(fmt, ...) wxLogNop() #else // !HAVE_VARIADIC_MACROS - WX_DEFINE_VARARG_FUNC_NOP(wxLogDebug, 1, (const wxString&)) + WX_DEFINE_VARARG_FUNC_NOP(wxLogDebug, 1, (const wxFormatString&)) #endif #endif // wxUSE_LOG_DEBUG/!wxUSE_LOG_DEBUG @@ -1458,6 +1556,11 @@ public: {} \ else \ wxMAKE_LOGGER(Trace).LogTrace + #define wxVLogTrace \ + if ( !wxLog::IsLevelEnabled(wxLOG_Trace, wxLOG_COMPONENT) ) \ + {} \ + else \ + wxMAKE_LOGGER(Trace).LogVTrace #else // !wxUSE_LOG_TRACE #define wxVLogTrace(mask, fmt, valist) wxLogNop() @@ -1465,9 +1568,9 @@ public: #define wxLogTrace(mask, fmt, ...) wxLogNop() #else // !HAVE_VARIADIC_MACROS #if WXWIN_COMPATIBILITY_2_8 - WX_DEFINE_VARARG_FUNC_NOP(wxLogTrace, 2, (wxTraceMask, const wxString&)) + WX_DEFINE_VARARG_FUNC_NOP(wxLogTrace, 2, (wxTraceMask, const wxFormatString&)) #endif - WX_DEFINE_VARARG_FUNC_NOP(wxLogTrace, 2, (const wxString&, const wxString&)) + WX_DEFINE_VARARG_FUNC_NOP(wxLogTrace, 2, (const wxString&, const wxFormatString&)) #ifdef __WATCOMC__ // workaround for http://bugzilla.openwatcom.org/show_bug.cgi?id=351 WX_DEFINE_VARARG_FUNC_NOP(wxLogTrace, 2, (const char*, const char*)) @@ -1517,5 +1620,14 @@ wxSafeShowMessage(const wxString& title, const wxString& text); #undef WX_WATCOM_ONLY_CODE #endif +// macro which disables debug logging in release builds: this is done by +// default by wxIMPLEMENT_APP() so usually it doesn't need to be used explicitly +#if defined(NDEBUG) && wxUSE_LOG_DEBUG + #define wxDISABLE_DEBUG_LOGGING_IN_RELEASE_BUILD() \ + wxLog::SetLogLevel(wxLOG_Info) +#else // !NDEBUG + #define wxDISABLE_DEBUG_LOGGING_IN_RELEASE_BUILD() +#endif // NDEBUG/!NDEBUG + #endif // _WX_LOG_H_